Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings
An Assessment of Community Impacts
(Sprache: Englisch)
Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings offers a detailed analysis for calculating the fire water demand required in buildings with existing and non-existant sprinkler systems. The installation of automatic sprinkler systems...
Voraussichtlich lieferbar in 3 Tag(en)
versandkostenfrei
Buch (Kartoniert)
53.49 €
Produktdetails
Produktinformationen zu „Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings “
Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings offers a detailed analysis for calculating the fire water demand required in buildings with existing and non-existant sprinkler systems. The installation of automatic sprinkler systems can significantly reduce the amount of water needed during a fire, but it requires water for commissioning, inspection, testing, and maintenance (CITM). This book provides an estimate of fire water used under both fire conditions, including CITM, to allow communities to develop fire water fees for both sprinklered and unsprinklered buildings that are proportional to the anticipated fire water usage.
The types of buildings analyzed include residential (family dwellings as well as those up to four stories in height), business, assembly, institutional, mercantile, and storage facilities. Water volume was studied using guidelines from the International Code Council, the National Fire Protection Association, and the Insurance Services Office.
Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings is intended for practitioners as a tool for analyzing water consumption in fire situations and for providing them with key information on the best types of water systems in a variety of buildings. Researchers working in building planning and safety will also find the book valuable.
The types of buildings analyzed include residential (family dwellings as well as those up to four stories in height), business, assembly, institutional, mercantile, and storage facilities. Water volume was studied using guidelines from the International Code Council, the National Fire Protection Association, and the Insurance Services Office.
Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings is intended for practitioners as a tool for analyzing water consumption in fire situations and for providing them with key information on the best types of water systems in a variety of buildings. Researchers working in building planning and safety will also find the book valuable.
Klappentext zu „Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings “
Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings offers a detailed analysis for calculating the fire water demand required in buildings with existing and non-existant sprinkler systems. The installation of automatic sprinkler systems can significantly reduce the amount of water needed during a fire, but it requires water for commissioning, inspection, testing, and maintenance (CITM). This book provides an estimate of fire water used under both fire conditions, including CITM, to allow communities to develop fire water fees for both sprinklered and unsprinklered buildings that are proportional to the anticipated fire water usage.The types of buildings analyzed include residential (family dwellings as well as those up to four stories in height), business, assembly, institutional, mercantile, and storage facilities. Water volume was studied using guidelines from the International Code Council, the National Fire Protection Association, and the Insurance Services Office. Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings is intended for practitioners as a tool for analyzing water consumption in fire situations and for providing them with key information on the best types of water systems in a variety of buildings. Researchers working in building planning and safety will also find the book valuable.
Inhaltsverzeichnis zu „Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings “
Introduction.- Community Selection.- Assessment of Fire Flow Fees.- Characteristic Set of Buildings.- Calculation of Fire Water Volume.- Calculation of Water Usage for Commissioning, Inspection, Testing, and Maintenance.- Fire Probability and Frequency.- Compiled Data (Probability and Volume).- Calculation of Fire Fees.- American Water Works Association (AWWA).- References.Bibliographische Angaben
- Autor: Inc., Code Consultants
- 2013, 2014, XIV, 62 Seiten, Maße: 15,3 x 23,6 cm, Kartoniert (TB), Englisch
- Verlag: Springer, Berlin
- ISBN-10: 1461481082
- ISBN-13: 9781461481089
Sprache:
Englisch
Kommentar zu "Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings"
0 Gebrauchte Artikel zu „Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings“
Zustand | Preis | Porto | Zahlung | Verkäufer | Rating |
---|
Schreiben Sie einen Kommentar zu "Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings".
Kommentar verfassen